| 
   
 |  | 
  
    | 
      | 
    
     Fatekh 
    Vergasov  | 
   
  
    | 
    
      Wish list
    
      notes for 
      memory
     | 
   
  
    
    
      
    
      
      City of Cupertino Code, Regulations, Rules, etc.
     
    
      
      
      Flag lot located here: 
21921 McClellan Road, Cupertino, CA 95014-4035
  
  Surveyor Map
  
  
  Zoning Map 
    
      
      My lot is not in Flood Hazard Area and in any Historic preservation list
     
    
      I want 
      totally demolish existing charming home and build a new one 
      with about 4,450 sq. ft. 
    
       
    
      a. 2,759 1st 
      floor 
    
      b. 1,241 2nd 
      floor, i.e. 45% of FAR on the second floor 
      
    
      c.    
      450 2 car garage
     
    
      must be as 
      follow: 
    
       
    
      1.
      
      Spanish or Mediterranean 
      Style and with ideas of 
      
      
      Feng Shui
    
      2. Two story 
      with 45% of FAR on the second floor 
    
       
    
      2.1. First 
      floor - about 2,759 sq. ft 
    
      2.1.1. Foyer 
      with closet, granite floor and high ceiling
    
      2.1.2. 
      Kitchen with bay-window
    
      2.1.3. Two 
      suits, i.e. BR with standard BA, or two BR with common double-sink BA
    
      2.1.4. 
      Living-room with gas burned fireplace
    
      2.1.5. 
      Family-room with wood burned fireplace
    
      2.1.6. 
      Full BA with toilet, sink and shower in tab
    
      2.1.7.
      Hidden stairway 
      to 2nd floor with one landing and not curve design, i.e. straight
    
      2.1.8. Den 
      (home office) transformable to guest BR
    
      2.1.9. 
      Ceiling height - minimum 9', where possible - slope (cathedral) ceilings
    
      2.1.10. 
      Pantry
    
      2.1.11. 
      Kitchen appliances - Thermador 
      style line with
      48" 
      refrigerator
    
      2.1.12. Front 
      door - Spanish style
    
       
    
      2.2. 
      Second floor - 1,241 sq. ft
    
      2.2.1. Master 
      BR
    
      2.2.2. Master 
      BA with steam-shower (6' x 5' with glass-door), whirl-pool, double sink and
      
      shower-toilet
    
      2.2.3. Two BR
    
      2.2.4. 
      Laundry (washer, dryer, ironing area, shelves)
    
      2.2.5. BA 
      with double-sink over granite countertop
    
      2.2.6.
      Attic furnace
    
      2.2.7. Slope 
      (cathedral) ceiling, were possible
    
      2.2.8. 
      Minimum  wall height - 6'-10" (Uniform building Code)
    
      2.2.9. To 
      avoid rain pelting noise - no sky windows 
    
       
    
      3. To make 
      utility service personal work easy, install both Gas and Electric meter on 
      on the front of driveway
    
      4. 12' paved 
      driveway width 
       
      (Fire department Standard)
    
      5. Garage: 2 
      car detached or attached
    
      6. No 
      basement. Just foundation
    
      7. Furnace heating-air-conditiong 
      system: separate to the 1st and 2nd floor (attic 
      furnace)
    
      8. Network, 
      Audio and Video 
      systems - wireless
    
      9. First 
      floor - hardwood floor (Brazilian charry)
    
      10. Second 
      floor - carpet or just Pergo
    
      11. Gutters, 
      downspouts - copper, if it is allowed by City code
    
      12. 
      Countertops, backsplashes, BA and laundry floors - granite
    
      13. Windows 
      and doors - wood - Pella or better Anderson
    
      14. 
      Insulation: compare regular bat insulation
      with more 
      effective one
    
      15. Stucco 
      color - best is white or any light
    
      16. Roof: 
      clay tile (not 
      
      Tapered barrel clay roof) 
      with roof-ventilation system from 
      O'Hagin
    
      17. BA walls 
      - marble on full height of the walls
    
      18. BA 
      floors: drain to be installed
    
      19. 
      Roof-windows: as far as possible, no such windows
    
      20. By
      Fire Code: make access 
      from outside to Main 
      Grounding bolt and nut (small box with lock)
    
      21. By
      Fire Code (16.40.280 
      and 16.40.290): 
      no fire sprinkler system necessary
    
      22.
      Sewer system without pump, i.e. sewer home outdoor 
      pipe to City service shall use natural gravity
    
      23. Grade - 
      to conform local sewer system code rules and 
      regulation: level of the first floor clean surface must be
      12" above the level of the nearest manhole
    
      24. Roof 
      overhung - 18" or more
    
      25.
  Fence task
  
  26.
  Main Intrans to 
  the Property
  27.
  Electric and Gas meter location 
  - in portion of the wall of the Main entrance 
     
    
    www.pseudology.org
       | 
   
 
 |