City of Cupertino, Department of Public Works IX. The following notes shell be shown (plus other notes deemed necessary by the Engineer): Developer's general notes: 1. All work shell be in accordance with the State of California Standard specifications (latest edition), Standard Plans (latest edition), and City of Cupertino Standard Plan. The Contractor shell perform the work described in specification, and satisfaction of the City Engineer 2. All underground utilities shell be installed and adequately backfilled before placement of the base material and surface structures. If utilities are to be installed subsequently, a written notification from the affected utility company indicating its commitment to bore or tunnel shall be submitted to the City. Engineer before proceeding with the work underground utilities, except storm and sanitary sewer , will not be permitted in pavement area, with the exception of street crossing , otherwise specifically approved and authorized by the city Engineer. 3. The Contractor shall have all of the utilities I underground mains, and services that may conflict with the project, located in the field. The contractor shall contact Underground Service Alert (USA) forty-eight (48)hours in advance of any work, for location of the underground facilities, at (800) 642-2444. 4. All trench backfill, fill areas, and base material shall attain a minimum 95% relative compaction as per standard Specifications. For typical trench sections refer to the city Standard Details, with the exception of sanitary sewers. 5. All trees, roots and foreign matter in existing or proposed Right of Way shall be removed to a depth of two (2) feet below sub grade and disposed of. 6. All existing pavement removed or damaged shall be replaced as required by the city Engineer 7. All concrete used for all structures must be Class "A" (6 sacks per cubic yard) as per Standard Specifications and shall attain a strength of 2,200 psi in seven (7) days. 8. Drop inlets installed shall be City of Cupertino Standard unless otherwise noted on the plans. The boxes shall be installed at the same time the P.C.C. curb and gutter is installed. Class "A" P.C.C. shall be used. 9. A minimum thickness of six (6) inches of P.C.C. shall be required for commercial driveway approaches and five (5) inches for residential. Locations shall be determined prior to the installation of the curbs. The driveway shall be installed at the same time as the curb 10. All street curbs shall be vertical vertical P.C.C. curbs 11. Install City of Cupertino street name signs, four (4) vertical blades each per assembly as shown on the plans 12. Install City of Cupertino Standard monument box (s) and monument (s) as shown an the plans 13. All grade stakes and laths required by the City Engineer shall be installed by the Sub-divider's Engineer as directed. Minimum off-sets for cut stakes shall be five (5) feet 14. Prior to commencing work, the Contractor shall have cut sheets approved by the city Engineer Notify the city Engineer twenty-four hours (24) prior to requiring inspection 15. The contractor shall submit a written request for final inspection 16. 0ne-half (1/2 pound of dispersing black shall be mixed with each cubic yard of concrete at the batch plant 17. Grading of lots outside of R/W as per typical section and for cross-section, shall be completed and approved by the City Engineer before proceeding with preparation of the sub-grade and placement of surface structures on lots All lots shall be graded to the street elevation, or as shown on the plans , or as determined by the city Engineer 18. Notify the City Engineer forty eight (48) hours in advance vertical of requiring services for checking field staking At this time, three (3) copies of the cut sheets will be furnished 19. All Standard street monuments , lot corner pipes, and other permanent monuments disturbed during construction shall be replaced before acceptance of the improvements by the city of Cupertino 20. Manhole frames and covers shall be brought to finish grade before final paving 21. The Developer shall pay all costs for moisture-density curves (Calif. Test No. 216E) and any other tests required by the city Engineer during street construction 22. Approval of the plans does not release the Contractor of the responsibility for corrections of mistakes, errors, or omissions contained therein. If , during the course of construction of improvements, public interest requires a modification of/or a departure from the City of Cupertino specifications or these improvements plans, the City Engineer shall have the authority to require such modification or departure and to specify the manner in which the same is to be complited 23. Septic tanks shall be pumped and backfilled to the satisfaction of Santa Clara Health Department prior to construction 24. For all five (5) foot monolithic sidewalks, all fire hydrants and electroliers shall be installed behind sidewalk 25. Each sheet of the construction/modification plans shall be initialed by the City Engineer to be considered approved final plans. It shall be the responsibility of the Contractor, and all subcontractors to insure they are furnished with approved plans or the latest revised plans 26. All water lines, valves, hydrants, and appurtenances thereto installed within the City of Cupertino Municipal Water Utility's service area, shall be property of said utility 27. Construction signing shall be installed prior to beginning of the work 28. Any and all storm lines, installed as part of the work on these plans, shall be cleaned of all excess material, debris and obstructions. Storm lines shall be flashed as directed by the City Engineer X. A legend will be required for any of the items, not included in the legend of standard Detail Booklet The legend may also include, if desired, the items shown in the Standard detail booklet XI. Sewerage system (to existing manhole or main) XII. Storm system (A) Permanent system of disposal (1) To existing manhole or main (B) Temporary system of disposal (approved system) XIII. City Bench Mark (latest City Datum) XIV. Original ground contours XV. Proposed pad elevations and existing adjoining pad elevations not to exceed two feet that lot adjoining side to side may exceed this difference in elevation where type "А" grade is provided Existing elevations at corners of adjoining lots of adjacent tract lots XVI. Type grading (FHA: A, В or C) XVII. Any signal gear involved in terms of installation shal require a complete signal plan and conductor schedule sheet XVIII. Standard City monuments |